Welcome to Digant Technologies, your partner for Telecom Automation & Monitoring Solutions!
Digant’s Intelligent Power Source Automation is used for switching the load automatically on to EB, Battery bank or DG based on the power source available at any given time and used for automating DG operations. The system monitors the grid supply, Telecom battery bank voltage, DG battery voltage and various alarms continuously, automatically starts and runs the DG set if the supply from the grid is not available and the battery bank voltage is lesser than pre configured threshold voltage. The system monitors and generates various alarms and makes efficient and optimal use of diesel generator in cases of non-availability of grid power.
EB on load
DG on load
Battery bank on load
DG Running Idle
Battery bank low voltage
DG battery low voltage
DG Freq out of range
LLOP/HWT
DG Fail to start
DG fail to stop
HRT (Optional)
Fire (Optional)
Parameter | Specification |
---|---|
Operating Voltage | 36VDC to 72VDC |
Telecom Battery Bank Monitor | Battery bank voltage measurement |
DG Battery Monitor | DG Battery low voltage detection |
Power Source Automation | Auto / Manual mode |
Phase Selector Modes | Single phase or two phase or 3 phase |
DG Automation | Auto DG ON / OFF |
PFC Alarm Outputs (NO,COM,NC) | 12 Channel |
Configuration Port | RS485 |
LED Indicators | Alarm outputs, EB and DG power source |
EB Contactor | 25A, 40A, 60A, 80A |
DG Contactor | 25A, 40A, 60A, 80A |
Load Current Supported | 25A, 40A, 60A, 80A |
SPD | Type 2 / class II |
Connectors For Alarms Output | Terminal block type |
Housing | IP63 |
Mounting | Outdoor |
Operating Temperature | -5°C to +60°C |
Humidity | 95% non-Condensing RH |
Alternating current distribution board panel is used for AC load distribution. It has Circuit Breakers of different current ratings to protect against overload and short circuit.
Parameter | Specification |
---|---|
MCB-AC Rated current |
6A ,16A,32A and 63A MCBs for each phase - 63Ax1,32Ax1,16Ax1,6Ax1 |
Rated voltage | 240 / 415V AC |
Rated Frequency | 50Hz |
Number of poles | 1P (Single pole) |
Rated short circuit breaking capacity | 10kA |
Rated insulation voltage | 660V |
Rated impulse voltage | 6kV |
Mounting | Wall mount (Indoor) |
DG Battery charger is suitable for charging 12V-100 / 130 / 180AH batteries used for engine start applications.
Parameter | Specification |
---|---|
Input Voltage | 150-300 V AC |
Output voltage Float Mode DC Boost Mode |
13.4 V DC 13.9 to 14 V DC |
Charging current in boost mode | 10 amps |
Charging current in float mode | 0 to 4 amps |
Protections Output over voltage (Batt charger included) Output short circuit and overload Battery reverse polarity |
15.5 V DC Continuously protected Protected latching mode |
Dimensions: L*B*H | 170x110x85mm |
Mounting | Wall mount (Indoor) |
Note : This product is available in four models
Integrated Intelligent Power Source Automation with 25A EB, DG contactors and MCBs, SPD,ACDB panel and DG battery charger – DTI2PSA1000
Integrated Intelligent Power Source Automation with 40A EB, DG contactors and MCBs, SPD,ACDB panel and DG battery charger – DTI2PSA1001
Integrated Intelligent Power Source Automation with 60A EB, DG contactors and MCBs,SPD, ACDB panel and DG battery charger – DTI2PSA1002
Integrated Intelligent Power Source Automation with 80A EB, DG contactors and MCBs, SPD,ACDB panel and DG battery charger – DTI2PSA1003